COGENERATION SETS
Cogeneration plants are designed
for combined production
of electric and heat power
as steam and/or hot water.
Electric power is directly related
to the mechanical power of the gas turbine.
As for heat power, it significantly varies
in a wide range depending on the selected waste heat recovery configuration
(steam or water type, combined steam and water type, or use of supplemental firing). The table below provides main parameters
of typical CHP units with steam recovery
boilers of 12-25 bars.
Implementation of additional low-pressure steam boilers of 3-6 bars pressure
or hot water units
for district heating are able
to increase heat power
by 25-35% over basic
unfired heat units.
Thermal Diagram
1 – Gas turbine engine
2 – Heat recovery boiler
3 – Generator
4 – Water tank
5 – Pump
6 – Heat consumer
Type Power, kW Electric Efficiency, % HUF
(Heat Utility Factor), %
Consumption
Electric Steam Hot Water Steam Steam
+
Hot water
Steam,t/h Fuel Gas,
ì3/h
Liquid Fuel,
kg/h
UGT 2500C 2750 4730 1000 27,5 75,0 84,8 6,3 1000 840
UGT 6000C 6000 8600 1900 30,1 73,2 82,8 11,1 2000 1680
UGT 10000C 9900 12900 2140 33,4 76,9 84,1 15,7 2980 2500
UGT 16000C 14500 18640 8400 27,9 63,8 79,9 24,5 5220 4380
UGT 15000C 16000 19500 4390 32,5 72,1 81,0 24,4 4940 4150
UGT 25 000C 25000 28500 7000 34,8 74,5 84,2 35,1 7210 6060
Barge mounted cogeneration heat and power plant
"Severnoye Siyaniye" rated 2x12 MW
6 MW modular cogeneration heat and power plant.
Poltava region, Ukrain